13
• Modifications
Changing the input or output range
To change the input or output range:
1. Remove the four screws holding the front panel in place (marked A &
B in the diagram below).
2. Remove the front panel. Take care not to lose the plastic insulators
which fit over the potentiometer screws - they are essential to
maintain specified isolation.
3. Select the switches according to the tables below.
Input
Switch Bank S1
Output
Switch Bank S2
LK4
Bit 1 Bit 2 Bit 3 Bit 4 Bit 1 Bit 2 Bit 3 Bit 4
4-20 mA ON OFF OFF OFF 4-20 mA OFF OFF OFF ON OFF
0-20 mA OFF OFF OFF ON 0-10 V OFF ON ON OFF OFF
0-10 V OFF OFF OFF OFF 0-5 V OFF ON ON OFF ON
±10 V OFF ON ON OFF
4. Replace the front panel.
5. Calibrate the unit.
LEFT HAND SIDE VIEW
D
E
G
H
B
A
C
F