17
3. Features
• Recognition and display of the most frequent installation errors:
short circuit, line/wire interrupt, line/wire mistakes, split pair
• Self test function and intermittent contact test
• Error display for each conductor by eight red conductor LED’s and one red LED for the shield (F).
• Display of no error by green LED (G).
• One key for ON, OFF and start of the test operation (D).
• Separate Step Key (H) to display list of multiple errors.
•
Automatic shut off of the IE-CT 30 seconds after the last use of key D or H.
• Nine switches define the pin assignment (C).
• Numeric display shows error type (B).
• 9 conductor attachment cord (A) for testing shielded installation lines and cables with up to 8
conductors.
• IE-CT Mainframe and IE-CT Test Boxes are equipped with RJ45 jacks (E and K) allowing also test
of patch cords.
• Protected against interference voltages up to 80 V AC/DC (100 V up to 5 minutes).
• Display of extraneous voltages for each conductor including readout of their polarity.
• Easy use and interpretation of the test results with given help on the IE-CT housing (I).
• Display for low battery power.
• Length of installation cable to be tested up to 1000 m.
• Automatic test operation is shown by flashing LED (G).
• Battery polarity reversal protection.
• Line identification by recognition of up to nine test boxes.
• Recognition and display for wrong set of pin assignment.
• Low power consumption for long battery life.
Komentáře k této Příručce