22
55 SSppeeiiffiiccaattiioonnss
EEMMVV
EN 61000-4-2 (ESD) 6kV/8kV
EN 61000-4-3 (radiated immunity)
ENV 50204 @AM 10V/average 80MHz - 1GHz
EN 61000-4-4 (burst) ~ 2kV; 2kV; I/O 1kV
EN 61000-4-5 (surge) 2/1kV
EN 61000-4-6 (conducted immunity)
ENV 50204 @10V 150kHz - 80MHz
EN 61000-4-11
EN 61000-4-29 (voltage variation)
EN 55022 (HF E)
conducted emissions 150kHz - 30MHz
radiated emissions 30MHz - 1GHz pp/average
radiated emissions 30MHz - 1GHz pp/qp
SShhoocckk-- uunndd vviibbrraattiioonn--tteesstt
IEC 60068-2-6 sinusoidal vibrations
frequencies: 5-9 Hz, amplitude: 3.5 mm
frequencies: 9-150 Hz, acceleration: 1g
IEC 60068-2-27 shock test, half-sinusoidal
shock acceleration: 15g (operating) 30g (non operating)
shock period: 11ms
EEnnvviirroonnmmeenntt--tteesstt
IIEC 60068-2-1 & IEC 60068-2-2
operating -40°C ... 75°C
non operating -40°C ... 75°C
IEC 60068-2-14 thermal shock
operating 0°C ... 60°C
non operating -40°C ... 80°C
IEC 60068-2-30 damp heat
22
CCeerrttiiffiiccaattiioonnss
UL Listed Industrial Control Equipment, certified1 for US and
Canada. .
CE marking within the EU
GOST R-certification (IEC standards with Russian deviations)
CCllaassss II DDiivviissiioonn 22
This equipment is suitable for use in Class I Division 2, Groups A,
B, C, and D or Non-Hazardous locations only.
Germanischer Lloyd (GL)
Komentáře k této Příručce